Flexible Fire Resistant Cables

Main Application:

Flexible fire resistant cables are mainly used for transmission lines of fire systems in high-rise buildings, underground buildings, hospitals, schools, business centers, department stores, museums and other buildings.

Features:

  • Excellent fire resistance and insulation performance.
  • Low smoke halogen-free performance.
  • Easy to bend, easy to install.

Technical Data

ModelBBTRZNGA-BTLYBTTRZ-YTTW
Insulation MaterialPEPEPE
Sheath MaterialPoPoPo
Wire Core MaterialAnnealed Round Copper Wire/Annealed Oxygen Free PUAnnealed Round Copper Wire/Annealed Oxygen Free PUAnnealed Round Copper Wire/Annealed Oxygen Free PU
Voltage0.6/1KV0.6/1KV0.6/1KV
Implementation StandardQ/CQHQ 07-2022Q/CQHQ 08-2022Q/CQHQ 08-2022
Fire Resistance Characteristics①Class A burns between phases at a flame temperature of 950 ºC and apply a voltage of 750V between the phases and the outer sheath for 90min without damage to the insulation.
②Class B burns at a flame temperature of 750 ºC-800 ºC and applies a voltage of 750V between the phases and the outer sheath for 90min without damage to the insulation.
950 ºC flame continues to be energized for 180min without breakdown.
②650 ºC flame after 15min to withstand 15min of water spray does notbreakdown.
950 ºC flame to withstand 15min of knocking vibration and not breakdown.
①Class A burns between phases at a flame temperature of 950 ºC and apply a voltage of 750V between the phases and the outer sheath for 90min without damage to the insulation.
②Class B burns at a flame temperature of 750 ºC-800 ºC and applies a voltage of 750V between the phases and the outer sheath for 90min without damage to the insulation.
Minimum cable bending radius
(D is cable diameter, unit: mm)
①D≤12, 12D
②12<D≤20, 20D
③20<D≤40, 30D
④D>40, 40D
①D≤12, 12D
②12<D≤20, 20D
③20<D≤40, 30D
④D>40, 40D
①D≤12, 12D
②12<D≤20, 20D
③20<D≤40, 30D
④D>40, 40D
Laying Environment: public buildings, high temperature occasions, dangerous places, underground places, transportation or transportation hubs and other places; Can be buried but do not have intermediate joints, can not be avoided to do waterproof treatment; Can be used for partial corrosion environment or pipe laying.

Application

Get A Quote!

Get a personalized quote today! Fill out our quick form and let us help you find the perfect cable solutions tailored to your needs.

Name
Phone/WhatsApp/WeChat
Email
Message
The form has been submitted successfully!
There has been some error while submitting the form. Please verify all form fields again.

You cannot copy content of this page

滚动至顶部